Power Quality Solutions

Elumotive Solutions

Power Quality Solutions for Industrial and Commercial Power Systems

Elumotive provides AHF, APF, SVG, STATCOM, UPQC, capacitor bank, reactor, and power quality components for projects that need harmonic mitigation, reactive power compensation, voltage stability, and reliable electrical performance.

Choose by Power Quality Problem

Harmonic Mitigation

Reduce THDi caused by VFDs, UPS systems, rectifiers, EV chargers, and other nonlinear loads.

View AHF / APF solutions →

Power Factor Correction

Improve power factor and reduce reactive power penalties for motors, compressors, cranes, and HVAC loads.

View SVG solutions →

Voltage Stability

Support stable voltage in systems with load impact, flicker, renewable energy integration, or medium-voltage networks.

View MV SVG solutions →

Capacitor Bank Protection

Avoid resonance, overheating, and premature capacitor failure in harmonic-rich systems.

View capacitor protection solutions →

Solutions by Industry

Manufacturing and VFD harmonic mitigation solution

Manufacturing and VFD Loads

Factories with multiple VFDs often face high THDi, transformer heating, nuisance tripping, and capacitor bank problems.

Recommended: AHF / APF
Data center and UPS power quality solution

Data Centers and UPS Systems

Improve upstream waveform quality for UPS, rectifier, and switch-mode power supply loads where reliability matters.

Recommended: AHF / UPQC
EV charging infrastructure power quality solution

EV Charging Infrastructure

Manage harmonic distortion and dynamic power demand from high-power EV chargers and charging stations.

Recommended: AHF + SVG
Renewable energy SVG and STATCOM solution

Renewable Energy and Microgrids

Support voltage stability, reactive power control, and grid connection quality for solar, wind, and microgrid projects.

Recommended: MV SVG / STATCOM
Heavy industry power quality solution

Steel, Mining and Heavy Industry

Support demanding loads such as rolling mills, cranes, hoists, welders, crushers, and large motor systems.

Recommended: SVG / STATCOM / AHF
Commercial building power factor correction solution

Commercial Buildings

Improve power factor and power reliability for office buildings, hospitals, campuses, airports, and infrastructure projects.

Recommended: SVG / Capacitor Bank

Solution Selection Guide

Main ProblemCommon LoadsRecommended Solution
High THDi / harmonic currentVFD, UPS, rectifier, EV chargerAHF / APF
Low power factorMotors, compressors, HVAC, cranesSVG or capacitor bank
Fast reactive power fluctuationCrane, welder, rolling mill, solar plantSVG / STATCOM
Capacitor overheating or resonanceCapacitor bank in harmonic-rich systemDetuned reactor + capacitor bank review
Harmonics and low PF togetherMixed industrial loadsAHF + SVG or UPQC
When should I use an active harmonic filter?

Choose an AHF when VFDs, UPS systems, or rectifiers create measurable current distortion, transformer heating, nuisance tripping, or capacitor problems. AHF output follows the load and targets selected harmonics.

When is an SVG better than a capacitor bank?

SVG is usually preferred for rapidly changing, unbalanced, or highly dynamic loads such as cranes, welders, rolling mills, and large motor starts. Capacitor banks are suitable for stable inductive demand when harmonic conditions are controlled.

Can a hybrid VAR system solve both power factor and harmonic issues?

Yes. A hybrid solution combines dynamic SVG compensation with capacitor capacity and can be configured for mixed loads, harmonic control, and project-specific voltage requirements.

Need a Power Quality Solution?

Send voltage level, transformer capacity, load type, THDi, THDv, power factor, and installation requirements.

Contact Elumotive